Analytical Case Study

ENEAGREEN: the original air cooling for press oil, designed for efficiency.

How a major Algerian customer revolutionised the press-oil cooling system in its production unit, abandoning water cooling towers in favour of ENEAGREEN.

  • -30% Energy consumption (up to)
  • -6 kW/h Hourly consumption reduced
  • -7°C Press oil temperature
  • Customer Ceramic manufacturer (confidential)
  • Location Batna, Algeria
  • Solution ENEAGREEN FIMO — Air cooling
01

The need for a high-performance, reliable cooling system

The customer is a well-known manufacturer in Batna, a major ceramic district in Algeria where numerous sector producers are concentrated.

A company that, with a view to continuous improvement, pays close attention to innovative and reliable technologies capable of delivering real benefits based on the factory’s needs and goals.

The latest objective: replace the old cooling-tower systems for press-oil cooling with a more efficient, higher-performing solution.

In summer, regional temperatures easily exceed 45°C: under these extreme conditions, water cooling cannot keep the oil below safety thresholds.

02

Extreme regional temperatures push water cooling into crisis

All the installed presses used the cooling-tower (water-based) system, which entails high water-treatment and maintenance costs and left the customer dissatisfied with results not in line with their needs.

In summer, regional peak temperatures very easily exceed 45°C: under these extreme conditions the water system cannot keep the press oil below the required thresholds. The risk of damage is concrete, and the customer wants a solution.

Temperatures over 45°C

In summer, extreme climate conditions push the water system beyond its operating limits.

Oil above threshold

The cooling tower fails to keep the press oil below safety thresholds, with a concrete risk of damage.

High water costs

High water-treatment and maintenance costs typical of cooling-tower systems.

Unsatisfactory result

Performance not in line with the customer's production needs.

03

Why switching to air cooling is necessary

During a meeting with the plant’s technical managers, all information on operating and environmental conditions was analysed.

The analysis result is clear: the systems in use cannot reach and maintain the values needed for safe operation under these conditions. Switching to an air cooling system is essential.

Parameter Previous solution New solution
Technology Water-based Air-based with variable ventilation
Maintenance High Minimal
Operating costs High Reduced
Hot-climate output Limited Optimal up to +45°C outside
04

ENEAGREEN, the original high-efficiency air cooling

ENEAGREEN is the original air cooling system and the most widely used in the ceramics industry. Designed by FIMO, a Sassuolo company with over 40 years of sector experience.

Among its various features, the ENEAGREEN model has a self-cleaning automatic fan-reversal system and a robust structure that makes it suitable for working even in the most challenging environments, with no need for particular maintenance.

Manufactured by FIMO — Sassuolo, Italy · 40+ years of experience
  • Variable airflow

    Ventilation adjusted to the real oil and outside climate temperatures.

  • Self-cleaning

    Automatic fan reversal → zero build-up of dirt and debris.

  • High performance

    Operational even above 45°C ambient temperature.

  • Energy saving

    Consumption reduced by up to 30% vs traditional systems.

  • Low noise

    Significant noise reduction compared with cooling towers.

  • Zero water

    Elimination of the water circuit and associated treatment and maintenance costs.

05

The start of the trial phase: two pilot units

In autumn 2022 the customer decided to start with 2 ENEAGREEN units, to assess results and performance against the old system: if satisfactory, replacing all cooling towers would be considered.

A few months later the customer declares full satisfaction: the oil-temperature instability problem is solved, as is the excessive maintenance, leading them to replace the other towers too with the appropriate ENEAGREEN models.

06

One year after installation: problem solved

Before

Overheated oil

Cooling tower

After

-7°C

ENEAGREEN

One year after installation, the customer confirms having solved the oil-temperature stability problem and eliminated the costs related to water-circuit consumption and maintenance, with better overall efficiency of the department.

Metric Result Impact
Energy consumption up to -30% Compared with traditional cooling-tower systems
Hourly consumption -6 kW/h Constant saving in production
Oil temperature -7°C Stability achieved even with outside temps over 45°C
Water circuit Eliminated No water treatment or maintenance cost
Plant extension All towers Full replacement after the pilot

What this case demonstrates

The ENEAGREEN case in the Algerian market shows how choosing to invest in reliable technological solutions tailored to the customer's needs not only delivers significant savings but makes the entire production unit more efficient.

01

Targeted investment

Identify the product best suited to meet the customer's needs based on their operational reality.

02

Reliable solution

An effective, reliable product, able to ensure performance and durability over time even in extreme working conditions.

03

Measurable saving

Significant reduction in consumption and costs, with fast ROI and low maintenance.

Next step

Got a similar situation?

If you run a ceramic line with similar technical challenges, we can help with targeted technical consulting.

07 Let's talk

Want to optimize your production line performance?

30 years in the ceramic industry. From diagnosis to solution, a single point of contact.